Research Article

The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial

Volume 28 · Issue 2 Publish Date: July 3, 2020
Full Text PDF
DOI
Serpil Yüksel
Department of Surgical Nursing, , Division of Nursing, Necmettin Erbakan University Faculty of Nursing, Konya, Turkey
Gülay Altun Uğraş
Department of Surgical Nursing, Mersin University Faculty of Nursing, Mersin, Turkey
Nurhan Altınok
Department of General Surgery, İstanbul University-Cerrahpaşa Cerrahpaşa School of Medicine, İstanbul, Turkey
Necla Demir
Department of General Surgery, İstanbul University-Cerrahpaşa Cerrahpaşa School of Medicine, İstanbul, Turkey
Yüksel, S., Altun Uğraş, G., Altınok, N., & Demir, N. (2020). The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial. Florence Nightingale Journal of Nursing, 28(2), 205–212. https://doi.org/10.5152/FNJN.2020.19119
Full Text Full Text PDF

Abstract

Aim: This study aimed to determine the effect of a cuff properly sized for mid-upper arm circumference on blood pressure measurement in obese surgical patients.

Method: This prospective crossover clinical trial was conducted with 100 patients who had body mass index ≥30 kg/m2 and mid-upper arm circumference ≥27 cm and were admitted to the general surgery unit of a medical faculty hospital in İstanbul, Turkey between January 1, 2015, and December 31, 2015. Blood pressure of the patients was measured using a small-sized adult cuff and a cuff properly sized for mid-upper arm circumference.

Results: Among the patients, 39% were morbidly obese and 67% had mid-upper arm circumference between 35 and 44 cm. Systolic blood pressure of the patients with a small adult cuff was 20.78 mmHg higher than that obtained with a cuff properly sized for mid-upper arm circumference, and their diastolic blood pressure was 10.15 mmHg higher on average (p<0.001). Only 6% of those with systolic hypertension according to the small adult cuff readings were found to have hypertension according to the cuff properly sized for mid-upper arm circumference (p<0.001).

Conclusion: The results showed that, in obese surgical patients, blood pressure is measured inaccurately and found to be falsely high when measurements are not performed using a cuff properly sized for mid-upper arm circumference.

Cite this article as: Yüksel, S., Altun-Uğraş, G., Altınok, N., Demir, N. (2020). The effect of cuff size on blood pressure measurement in obese surgical patients: A prospective crossover clinical trial. Florence Nightingale Journal of Nursing, 28(2), 205-212.

Similar Articles

Article Info
Published In
Journal Florence Nightingale Journal of Nursing
Volume / Issue Volume 28 · Issue 2
Pages 205-212
History
Published Online July 3, 2020
Copyright
Affiliations
Serpil Yüksel
Department of Surgical Nursing, , Division of Nursing, Necmettin Erbakan University Faculty of Nursing, Konya, Turkey
Gülay Altun Uğraş
Department of Surgical Nursing, Mersin University Faculty of Nursing, Mersin, Turkey
Nurhan Altınok
Department of General Surgery, İstanbul University-Cerrahpaşa Cerrahpaşa School of Medicine, İstanbul, Turkey
Necla Demir
Department of General Surgery, İstanbul University-Cerrahpaşa Cerrahpaşa School of Medicine, İstanbul, Turkey
Cite this Article
Yüksel, S., Altun Uğraş, G., Altınok, N., & Demir, N. (2020). The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial. Florence Nightingale Journal of Nursing, 28(2), 205–212. https://doi.org/10.5152/FNJN.2020.19119
Outlines